FAQ - Audio SRCs

Sample Rate Converters

[Q0062]
・Regarding the data output, what is the output level of SDTO after outputting LSB data? 
(Indefinite, H level, L level?)
A.
・The SDTO pin output is Low level after sending LSB data.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0063]
・What happens to the trailing data after inputting LSB data that has longer bit length than the input bit length setting? 
 For example, what happens to the lower 4-bit if the input data is 24-bit when input data bit length setting is 20-bit?
A.
・Lower LSBs are not taken into the internal SRC.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0064]
・What happens to the SRC output when zero data is input SRC inputs with the DITHER setting ON?
A.
・The SRC device outputs zero data.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0065]
・How long is group delay of the AK4121A?
A.
・Group Delay can be calculated by the following formula. It depends on the format of the output port. 
 1. Output format is LSB/MSB justified: 
Group Delay = 55/fsi + 2.5/fso 
 2. Output format is I2S: 
Group Delay = 55/fsi + 2.0/fso 
 (Sample Rate input: fsi, output: fso) 
 However, there are variations in group delay, the max. of 1/fsi or 1/fso depending on the data latch timing.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0066]
・What happens if the external LRCK/BICK input stops on the AK4127? After that, will the AK4127 return to normal operation by resuming clock input (BICK, LRCK, SDTI data)?
A.
・When LRCK/BICK input is stopped, the built-in PLL enters UNLOCK state and the SDTO output becomes zero data. At this time, the output data suddenly becomes zero, so pop noise will be generated. It is possible to avoid pop noise by soft mute function or inputting zero data. When LRCK / BICK is input again, the PLL locks and normal power-up operation is executed. Normal data can be output 100 ms after clock input.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0067]
・How long is group delay of the AK4127?
A.
・Group delay of the AK4127 is as follows. 
 Group Delay: 54/fsi + 2/fso 
 (fsi: sample rate of input port, fso: sample rate of output port) 
 However, there are variations in group delay, the max. of 1/fsi or 1/fso depending on the data latch timing.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0068]
・What should I care about when selecting the reference clock (REFCLK) of the PLL of the AK4127?
A.
・There are advantages if the reference clock frequency is faster. PLL is more easily locked and the lock time is quicker.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0069]
・Is it possible to convert TDM format data (48 KHz, 24-bit) to 4 channels of non-TDM I2S format data (44.1 KHz, 16-bit) with the AK4128A in input synchronous mode?
A.
・Yes, this is an example of how it is variously possible to convert TDM/non-TDM, I2S/MSB/LSB justified, sample rate, and bit length.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0070]
・Is the master clock input (IMCLK) of the input port necessary to work on the sample rate conversion on AK4128A ?
A.
・The master clock input is not necessary to work SRC function. Data is clocked to IBICK, ILRCK. 
The master clock input could be used as the master clock of the device connected to the output port in bypass mode.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0071]
・How long is group delay of the AK4128A? 
As there are "DEM", "FIR" and "SRC" functions in the block diagram, does the "FIR" block have the most of group delay? 
Does group delay occur in the "DEM" or "SRC" block?
A.
・Group delay value of the AK4128A is 54/fsi + 10/fso (typ.). 
However, there are deviations of about ±1/fs. (55/fsi + 9/fso or 53/fsi + 11/fso) 
Most of delay time is occurred in the FIR block (54/fsi). 
There is no delay in the DEM block. The rest of delay time is generated at the SRC block (10/fso).
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0072]
・How long is group delay in the bypass mode of the AK4127, AK4128A and the AK4129?
A.
・It depends on Audio data format of input and output port on the condition of the same phase between Input LRCK and Output LRCK. 
 Input port  →  Output port 
 I2S              →  LSBJ/MSBJ :  1.5/fs 
 I2S              →  I2S              :  1.0/fs 
 LSBJ/MSBJ   →  LSBJ/MSBJ :  1.0/fs 
 LSBJ/MSBJ   →  I2S               :  0.5/fs 
 However, there are variations about 1/fs.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0073]
・When the AK4129 converts 24-bit input to 16-bit output, how is the remaining LSB 8 bits processed?
A.
・The SRC block is processed with 24-bit data. However, when 16-bit output setting is selected, the result of SRC is rounded into 16-bit and output, with dither added to the LSB if dither is enabled.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0074]
・Is the following conversion possible with the AK4129? 
TDM data input (fsi=192/96kHz) → TDM data output (fso=48kHz)
A.
・The AK4129 supports TDM mode, but does not support fs 192KHz and 96KHz. The maximum sample rate is up to 48kHz in TDM mode for both input and output ports.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0075]
・Is the following conversion possible with the AK4129? 
2x asynchronous TDM data input (fsi=48kHz) → TDM data output (fso=96kHz)
A.
・The AK4129 does not support two asynchronous TDM input sources. The sample rate at the output port is also out of spec.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0076]
・Is the following conversion possible with the AK4129? 
TDM data input (fsi=48kHz) + I2S 2ch data input (fsi=48kHz) (Input sources are asynchronous) → TDM data output (fso=96kHz)
A.
・The AK4129 does not support TDM and I2S at the same time on the same port. The sample rate at the output port is also out of spec.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0077]
・Is the following conversion possible with the AK4129? 
3 x I2S data input (fs=48kHz) → TDM data output (fs=192 kHz)
A.
・The AK4129 does not support 192kHz in TDM format on the output port. The output port supports TDM format up to fso = 48kHz. Three streams of I2S format data on the input port are available in both synchronous and asynchronous mode.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0078]
・The AK4129 supports 32-bit BICK/data slot in TDM format in the specifications. Is 24-bit BICK/data slot supported in TDM mode?
A.
・The AK4129 supports only 32-bit BICK/data slot in TDM mode.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0079]
・The datasheet says "it should be reset by the PDN pin or RSTN bit in serial control mode" when external clock is changed. Without PDN pin/RSTN bit setting, what happens with the output of the AK4129?
A.
・The AK4129 may generate pop noise when the external clock is changed without PDN pin/RSTN bit setting. An alternative way to avoid pop noise is to put the AK4129 into mute state when changing clocks.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0080]
・When using a single AK4128A for an 8ch input system and operating it in synchronous mode, is there any phase shift on 8 channels?
A.
・There is no phase shift on 8 channels.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.
[Q0081]
・When using two of AK4128A's for a 16ch input system and operating them at the same time in synchronous mode, is there any phase shift between two AK4128A's (16ch output)?
A.
・The SRC block of the AK4128A is operated by built-in OSC. Even if the external clocks (IBICK, ILRCK, OBICK, OLRCK) are the same on the two AK4128A's, the conversion timing will not be exactly the same because each device has a free-running clock that influences the conversion timing. 
This means there may be some small signal phase shift reflected in the SRC output data.
Was it helpful?
Yes
No
Thank you We will reflect your opinion on the improvement of the web content.