RDS (Refrigerant Detection System)
Flammable Gas Sensors
RDS R32
RDS R32 (Sense Air)
The RDS module is designed for detecting refrigerant leaks in mildly flammable refrigerants classified as A2L, including R32 and R454 A/B/C. The protective housing shields the sensor core from dust and water droplets, ensuring reliable operation. Additionally, it features an integrated heating element, enabling functionality even in cold environments.
The module supports the Modbus protocol, allowing measurement data to be transmitted to control systems. It also includes an additional output pin that activates a digital output signal when the detected gas concentration reaches a configurable threshold. The output can be set to either a digital PWM signal or an analog linear output, providing flexibility in how the data is used.
Key features
Specifications
Product name |
RDS R32 |
---|---|
Measured Gas | R32, R454A, R454B, R454C |
Product number | 009-3-0007: 24V 009-3-0008: 12V 009-3-0009: 5V |
Measurement range |
0 - 50% LFL |
Accuracy (*) |
±2.5% LFL |
Response time (**) |
<30s |
Power supply |
009-3-0007: 24V±10% VAC/DC 009-3-0008: 12V±10% VDC 009-3-0009: 5V±10% VDC |
Output | Digital signal (High/Low or PWM) or Analogue voltage or Analogue current. |
Communication(***) |
Modbus over RS-485 |
Dimensions |
113 x 65 x 40 mm |
Operation Temprature range |
-40 - 70℃ |
IP Rating |
IP66 & IP67 |
Compliance with IEC 60335-2-40 ed.7 |
yes |
Compliance with UL 60335-2-40 ed.4 |
yes |
[Notes]
* 0 - 25%LFL and -30 - 60℃, After 3 ABC period or 1 zero calibration
** When exposed to R32 with concentration 25% LFL or higher, and Detection Threshold Limit Value set to 10% of LFL (default factory setting)
*** 009-3-0009 Senseair RDS R32 5V is hardware configured for UART communication and digital output (no RS-485 or analogue outputs are available on this variant)